CASE STUDY · MODELLED PLANT · UNITED STATES

Northline Foods — four LPG boilers, flue gas 187 °C down to 50 °C

A US food plant with four gas-fired boilers, modelled at nameplate in Heattech Pulse. The two-pass condensing unit takes the flue gas from 187 °C to about 50 °C and the feedwater from 30 °C to 85 °C, and the fuel bill falls by roughly a tenth — recomputed every minute from the plant's own signals.

Plant profile

PlantNorthline Foods — 4 boilers (UB-01, UB-02, UB-03, UB-04)
Location / gridUnited States · America/Chicago · USD
Capacity18.6 t/h steam across 4 boilers · 13,910 kW installed
FuelLPG (propane/butane) · NCV 45.9 GJ/t · CO2 2.985 kg per kg fuel
Heat recovery unittwo-pass condensing economizer (DXL)
Operating hours8,000 h / year
DataSimulated instrument signals on the plant model — 1-minute samples

Baseline — what the stack was throwing away

The 4 boilers together fire 932 kg of fuel an hour and leave the stack between 186.5 °C and 187.2 °C. The flue-gas dew point is 56.7 °C, so everything above it is heat the plant paid for and did not use. Feedwater arrives at 29.8 °C.

BoilerLoadFuelFlue in / outWater in / outHRSaved
UB-0185.8 %114 kg/h186.5 → 50.2 °C29.8 → 85.0 °C114 kW9.94 %
UB-0270.8 %157 kg/h187.2 → 50.7 °C29.8 → 85.0 °C153 kW9.74 %
UB-0364.7 %229 kg/h187.1 → 50.6 °C29.8 → 85.0 °C225 kW9.79 %
UB-0483.4 %432 kg/h186.5 → 50.5 °C29.7 → 85.0 °C423 kW9.80 %

Solution

The condensing stage sits after the boiler and before the stack: flue gas passes the tube bundle, water passes the other side, and the unit is controlled to keep the stack above its minimum while still condensing. Effectiveness at this load is 87.0 %, with the stack margin held at 5.2 °C above the dew point.

Measured results

MetricValueNote
Heat recovered, right now915 kWflue side and water side balanced
Fuel not purchased101 kg/h · 9.80 %share of the fuel bill
Condensate collected341 kg/hcounted, not estimated
Boiler efficiency80.4 % → 89.3 % (GCV)before → after
Cost per tonne of steam69 → 62 USDfuel + water
Fuel cost avoided$98/hat 1 USD/kg

Savings and payback

PeriodFuel not purchasedHeat recoveredMoney savedCO2
Since commissioning43.4 t485.4 MWh$41.5k129.7 t
Per year (8,000 h)810 t7,319 MWh$780.4k2,418 t

Water saved is condensate actually collected: 191.1 m3 since commissioning. No carbon price is added unless stated — the CO2 column is physical avoided CO2 at 2.985 kg per kg of fuel.

Verification method

IPMVP Option B in structure: a measurement boundary drawn around boiler and economizer, continuous measurement of fuel, flue temperature and water flow/temperature, and savings computed from the measured heat recovery rather than from a design curve. The instrument signals are simulated from the boiler nameplate and the heat-recovery unit datasheet, and every number on this page is recomputed live from those signals — no customer and no invoiced saving is claimed.

Heattech Pulse dashboard — Northline Foods: 101 kg/h fuel not purchased, 915 kW heat recovered, $41.5k saved since commissioning
Northline Foods as it runs in Heattech Pulse — overview, fuel and water not purchased, CO2 avoided.

Open the live plant →