CXL and DXL · condensing

CHR — condensing heat recovery, built as CXL and DXL

The water vapour in your flue gas carries real energy — and most plants send it up the stack. CHR pushes the gas below its dew point, condenses that vapour, and recovers both the latent heat and the water. This is the part almost nobody measures.

409 kWlatent heat recovered right now
337 kg/hcondensate recovered — the water you no longer buy
140.0 m³water recovered since start

Why there is energy in the vapour

Burning LPG produces water vapour as a combustion product. That vapour holds 2,257 kJ per kilogram of latent heat. While the gas stays above its dew point (54.6 °C on this plant) that energy stays in the gas phase and leaves with the stack. Condense the vapour and the heat comes out — into the same feedwater loop CHR already uses.

The condensate itself is water you would otherwise buy and treat. On this demo plant 140.0 m³ has already been recovered, measured on the drain line.

Measured performance · Northline Foods (demo)

Measured on the demo plant over the same window: 8.47 % of fuel saved, IPMVP Option B, boundary = boiler plus economizer. One number per plant, re-derivable from the four metered streams.

The latent leg is the vapour that actually condenses between 77 °C and 49 °C, taken from PULSE's loss model (latent share of the fuel × condensed fraction at 49 °C). We measured 8.47 % of fuel on the demo plant (Avis Foods), IPMVP Option B, boundary = boiler + economizer. The split into an above-dew-point leg and a latent leg is reported only where the second flue-gas temperature pair exists — on DXL, under How the saving is measured.

Engineering that makes condensation safe

One product · two configurations

CHR — condensing heat recovery (CXL / DXL)

One product line, two configurations: CXL with one stage and DXL with two. Both cool the flue gas to 77–49 °C (170–120 °F), below the water dew point, and both land on the same measured saving — the difference is only where the recovered heat is sent.

The two configurations

CXL — single stage

Cain CXL single-stage condensing economizer
CXL — single-stage condensing economizer, one casing, one heat sink.
CXL single-stage installation schematic on a steam boiler: boiler exhaust through the condensing economizer, cold makeup or process water in, heated water out, bypass for low load
CXL installation: boiler exhaust through the condensing economizer, cold makeup or process water in, heated water out, bypass at low load.
  • One condensing stage: all recovered heat goes into one stream.
  • Heat sink: makeup water or process water.
  • Fewest connections, simplest piping, lowest installed cost.
  • Choose it when a steady flow of cold makeup or process water is available.

DXL — two stage

Cain DXL two-stage condensing economizer
DXL — two-stage condensing economizer, one casing with hinged access doors.
DXL two-stage installation schematic on a steam boiler: flue gas through both condensing stages, boiler feedwater heated in stage 1, makeup water in stage 2, condensate drained at the base, bypass for low load
DXL installation: boiler feedwater preheated in stage 1, makeup water in stage 2, condensate drained from the base, bypass at low load.
  • Two condensing stages in series: stage 1 preheats boiler feedwater, stage 2 preheats makeup water.
  • Heat sink: feedwater first, makeup water second.
  • Choose it when makeup water is limited or intermittent — feedwater flow keeps the unit condensing.
  • Highest total annual recovery of the two, because condensing hours do not depend on makeup demand.

Why both cool to the same temperature

Both are condensing exchangers built for the same physical job: taking the flue gas from 149–427 °C down to 77–49 °C, below the water dew point of the gas. That exit temperature is the target, not a coincidence. What differs is where the recovered heat is sent, and how many hours a year the exchanger stays in the condensing range.

How the saving is measured

CXL is measured once. The boundary is the boiler plus the economizer: flue-gas enthalpy in and out, and heat absorbed by the makeup or process water, corrected to steam output. One number comes out — 8.47 % of fuel on our demo plant (Avis Foods), IPMVP Option B. No split is reported for CXL.

DXL adds a second stage, so it carries an extra flue-gas temperature pair — gas in and gas out of the condensing stage — which measures the additional heat taken from the flue gas. That pair is what splits the same 8.47 % into 5.92 % recovered above the water dew point and 2.55 % from latent heat. Both numbers are measured on the same demo plant, not a catalogue figure.

Model selection by duty

Codes are ours, in 100 kW steps; the code follows the required duty at the flue-gas conditions above.

Code CXLCode DXLDuty (kW)Boiler (t/h steam)LPG (kg/h)Flue gas (kg/h)Sensible (kW)Latent (kW)
VX-CXL-0100VX-DXL-01001001.3721.3265248
VX-CXL-0200VX-DXL-02002002.51432.65210496
VX-CXL-0300VX-DXL-03003003.82153.977157143
VX-CXL-0400VX-DXL-04004005.12875.303209191
VX-CXL-0500VX-DXL-05005006.33586.629261239
VX-CXL-0600VX-DXL-06006007.64307.955313287
VX-CXL-0700VX-DXL-07007008.95029.281365335
VX-CXL-0800VX-DXL-080080010.257310.606418382
VX-CXL-0900VX-DXL-090090011.464511.932470430
VX-CXL-1000VX-DXL-1000100012.771713.258522478
VX-CXL-1100VX-DXL-1100110014.078814.584574526
VX-CXL-1200VX-DXL-1200120015.286015.910626574
VX-CXL-1300VX-DXL-1300130016.593217.236679621
VX-CXL-1400VX-DXL-1400140017.8100318.561731669
VX-CXL-1500VX-DXL-1500150019.0107519.887783717
VX-CXL-1600VX-DXL-1600160020.3114721.213835765